Sita UV 107 System
SITA UV 107 system
The SITA UV 107 system is used to disinfect (drinking) water streams with a low flow. This 107 version can disinfect up to 5 liters per minute (300 liters per hour, T=99%) with a safe dose of at least 300 J/m2 making the water bacteriologically pure after treatment. This is a complete system with adapter, radiation chamber, uv lamp and quartz tube. You can get started right away.
The smaller SITA systems are often used in air humidification, dental offices, but also in campers and yachts.
The SITA UV systems are completely made of stainless steel and are characterized by a very high quality and long life.
Would you like a customized offer? Please contact us.
What is supplied with this SITA UV 107 system?
- UV lamp (9000 hours burning time)
- Stainless steel reaction chamber
- Quartz tube + O-ring + reducer 230V adapter + connection UV lamp
- Connections: 1/8″ F
- 12 VDC available.
The advantages of Sita’s UV-C systems:
- Disinfects water without the addition of chemicals, so safe!
- Makes viruses, bacteria and fungi harmless.
- Easy to install.
- Low maintenance.
- Polished inside and out for extra efficiency.
- Solid European manufacturing.
- Spare parts are available quickly, usually from stock.
What does the T-value mean?
This means the “Transmission Value” or clarity of the water. It is indicated in this case as 99% at 1 cm from the lamp. If the water is less clear, the UV dose will be lower.
For example, tap water is around 85-90%. Water from a water tank can be as low as 70%.
What can I do when I have a lower transmission value?
You could treat the water yourself with a carbon filter, for example. It is also possible to take a heavier UV system.
The lamp still works after 9000 hours. Should I change it?
Yes! The lamp will still emit blue light however, over time its frequency will become too low for proper disinfection.
Do I need to clean the quartz tube?
The quartz tube is the barrier between the water and the UV lamp. The cleaner it is, the better it allows the UV light to pass through.
We recommend cleaning this quartz tube when changing lamps. You can do this by soaking it in citric acid and then rubbing it with medicated alcohol.
Also inspect the condition of the O-ring and replace it if necessary.
Technical specifications Sita UV 107 system
| UV-C dose @ UVT 99% – 1cm | > 300 J/m2 (9,000 h) |
| Lamp lifespan | 9.000 h |
| Manifold material: stainless steel | AISI 304 |
| Max. pressure | 9 bar |
| Electrical supply | 230 V – 50/60 Hz |
| Max. flow rate (l/min) | 5 |
| Number of lamps | 1 |
| IN-OUT connections | ? ? “F |
| Fault/working led | yes |
| Power consumption (W ± 2%) | 12 |